Fire Safety Management Services

Stallion Fire Safety services assures that our clients properties and assets are well managed in terms of mitigating any types of fire incidents. The fore most important component is the prevention of fire. In this respect our well experienced fire engineering team designs according to the regulatory codes and up to the international standards and client requirement. Our solutions include design, Installation, Commissioning and after sales service for all Fire Safety Systems. The training wing will be responsible for continuous training of our staff and client staff on a retainer basis.

Services rendered under the emergency management
From the reassuring presence of uniformed staff to full
corporate security coverage across a range of venues or
events, our comprehensive security packages help to
create a safe and comfortable corporate environment.
Our team of experienced security personnel, including
army and police background security personnel, are
available for:
Preparing A customized Disaster Management Procedure
(DMP) including training the Management and Team
members according to the client requirement

AUTOMATED AND MANUAL OPERATED FIRE FIGHTING SYSTEMS

Dry Riser System

Dry fire main water supply pipe installed in a building for fire-fighting purposes, fitted with inlet connections at fire service access level and landing valves at specified points, which is normally dry but is capable of being charged with water usually by pumping from fire and rescue service appliances.

Wet Riser System

Wet fire main water supply pipe installed in a building for fire-fighting purposes and permanently charged with water from a pressurized supply, and fitted with landing valves at specified points. Where fire mains are installed and there are no floors higher than 50 m above fire service access level, wet or dry fire mains may be installed.

Hose Reel System

Fire hose reel systems consist of pumps, pipes, water supply and hose reels located strategically in a building, ensuring proper coverage of water to combat a fire. The system is manually operated and activated by opening a valve enabling the water to flow into the hose that is typically 30 meters away.

Drencher System

These systems are used for fire protection of technologies and objects where it is possible to use water as the extinguishing agent. They are intended mainly for extinguishing, cooling down, preventing the radiant heat from spreading, cooling down surfaces of buildings, steel structures and technological equipment.

Hydrant System

The fire hydrant system is the backbone of the firefighting systems in a building or premises. The system is a water distribution system consisting of water tank, suction piping, fire pumps and a distributed piping system. The distributed piping system establishes connectivity throughout the building or premises through fire hydrants, hoses and nozzles.

Sprinkler System

Automatic fire sprinkler systems also known as a wet pipe system are widely regarded as the most effective method of controlling fires caused by a broad range of hazards. With experience, Stallion offers end-to-end fire sprinkler systems to protect your people, business and assets.

Fire Alarm System

Fire detection systems are designed to discover fires early in their development when me will still be available for the safe evacuation of occupants. Property loss can be reduced and downtime for the operation minimized through early detection because control efforts are started while the fire is still small.

CO2 Suppression System

Carbon dioxide suppresses fire without leaving behind any residues after discharge thus avoiding damage to sensitive equipment. With no agent clean up, there is less downtime after an incident. When properly designed, the carbon dioxide system will suppress fire in Class A, B, and C hazards by displacing the air containing oxygen that supports combustion.

FM200 System

FM-200 has established itself as one of the most popular clean fire suppression agents. This is due to its ability to quickly knock down Class A, B and C fires with no risk of thermal shock damage to delicate equipment. FM-200 is electrically non-conductive and non-corrosive; it leaves no residue.

Foam Pouring System

Commonly protect any areas that involve the storage, processing or transportation of flammable liquids and include Bladder Tanks and Fixed Foam Skids. The principle of a Foam Proportioning Systems is to produce Low, Medium or High Expansion Foam to smother or blanket an area of combustion or potential risk.

Kitchen Hood Wet Chemical System

Wet chemical suppression system
is used to protect modern
commercial kitchen from potential
threats like open flame, red hot
cooking surface and heavily
grease laden environment which in
turn leads to oil and grease fires.

Modular Fire Extinguishers

For round the clock protection, for
unmanned areas. Doesn’t require
cumbersome piping, easy to install,
and available in Dry powder and
Clean Agent Variants. Modular Fire
Extinguishers are fitted with an
automatic sprinkler valve, that can
be calibrated to discharge at an
ambient temperature of 57°C.
68°C, 79°C, and 93°C. They dont
depend on an external source of
energy and can be oprated
electrically or machanically for
their operation.

Super Fire Ball

Super Fire Ball is the easiest and
fastest fire extinguisher to interfere
the local fires.
This fabolous devise is
non-pressurised container made
with polystrene. It contains Dry
Chemical Powder that has been
developed from Boron Mineral and
micronised specifically for Super
Fire Ball.
This Activation Mechanism works
with the fuse detection (which
allows the ball to function within 1-5
seconds).

EXCLUSIVE DISTRIBUTOR

Stallion Security Consultancy Services

Stallion security consultancy services also provides support services within the area
of consultancy. Our expertise encompasses:

Private Confidential Background Checks and Commercial Inquiries
Security reviews and risk assessments
Technical security systems
Food & health safety
Workplace safety
Emergency management
Training requirements
Fire safety